LegalTips.ORG Directory Full Text About us
Alabama Code | California Code | Connecticut Code | Nebraska Code | Texas Code
 
Google
 
Web LegalTips.org


maritime & jones injury law attorney   Official Government Sites
   State of Alabama
   State of Alaska
   State of Arizona
   State of Arkansas
   State of California
   State of Colorado
   State of Connecticut
   State of Delaware
   District-of-Columbia
   State of Florida
   State of Georgia
   State of Hawaii
   State of Idaho
   State of Illinois
   State of Indiana
   State of Iowa
   State of Kansas
   State of Kentucky
   State of Louisiana
   State of Maine
   State of Maryland
   State of Massachusetts
   State of Michigan
   State of Minnesota
   State of Mississippi
   State of Missouri
   State of Montana
   State of Nebraska
   State of Nevada
   State of New-Hampshire
   State of New-Jersey
   State of New-Mexico
   State of New York
   State of North-Carolina
   State of North-Dakota
   State of Ohio
   State of Oklahoma
   State of Oregon
   State of Pennsylvania
   State of Rhode-Island
   State of South-Carolina
   State of South-Dakota
   State of Tennessee
   State of Texas
   State of Utah
   State of Vermont
   State of Virginia
   State of Washington
   State of West-Virginia
   State of Wisconsin
   State of Wyoming

Section 25-9-82

Standards and procedures as to gases and air quality.

(a) Air in which men work or travel must promptly be improved if it contains less than 19.5 percent oxygen, more than one percent carbon dioxide or is contaminated with noxious or poisonous gases.

(b) If the air immediately returning from a split that ventilates any active workings contains more than one percent methane or more, the ventilation shall be improved, and, if it contains 1.5 percent or more of methane, the power shall be cut off from the portion of the mine affected, and the employees shall be required to withdraw until ventilation is improved.

(c) Face work must be stopped, power to face equipment cut off and the employees ordered and required to withdraw until ventilation is improved, whenever one percent or more of methane can be detected on an approved type methane detector or whenever gas can be detected on a permissible flame safety lamp at any point not less than 12 inches from the roof, face or rib. This does not apply to other faces in the entry or slope in which work can be safely continued.

(d) When entries or faces are stopped on account of gas for ventilation to be improved, only employees designated to work on improving the ventilation under competent direction may be permitted in the affected area. Power shall not be restored until ventilation is improved.

(Acts 1949, No. 207, p. 242, §14; Acts 1959, No. 347, p. 937; Acts 1975, 4th Ex. Sess., No. 147, p. 2866, §1.)